elinex.

Elinex is the manufacturer of the EL Powerconditioners. The powerconditioner is the security when it comes to suppressing mains voltage pollution and overvoltage due to indirect lightning. All electronic equipment, or equipment which is provided with switched power supplies, is hereby protected. Virtually all electronic systems nowadays use switched power supplies.

Elinex Power Conditioner - EL 250 GW

Summary.

The EL Power conditioner is the best solution for network pollution and other issues that affect the electronic systems through the power supply. The power conditioner is part of the conditioning concept, as Elinex mainly implements this within the Retail sector, with major segments supermarkets and the hospitality sector. Cash-automation is widely used within these segments, and this automation often causes malfunctions. The power conditioner is currently the device with which these failures can be removed. In addition, the power conditioner finds extensive application in the medical sector where IEC 601-1-1 is required. Also in an industrial environment where the controller is prevented by network connections from network voltage pollution, the power conditioner ensures that everything remains functional.

We gladly assist with the selection for the right solution regarding your mains voltage problems. A network voltage analysis may be interesting for your system.

Contact one of our specialists on +31 180 72 13 59 or let us know by filling in your information below.

Features.

TECHNICAL SPECIFICATIONS.

  • Power range 250VA to 1000VA;
  • Suppression of network pollution for both in normal mode and common mode and the corresponding crossings;
  • Suppression of inductive lightning energy according to IEEE 587, 6 KV cat. B, zone C according to VDE-0675 and cat. III according to IEC-664;
  • Maximum residual voltage normal mode = <10 Volt, common mode = <0.5 Volt and crossings = <0.5 Volt (at IEEE 587.6 KV cat. B);
  • Low impedance transformer;
  • Suppressive interactive noise;
  • Reduce leakage currents to below 100 uA according to IEC 601 (certificate optional);
  • 5 Year Warranty RoHS Compliant.

More information about Elinex.

Please contact one of our specialists to discuss a possible solution and / or to request more information. Please e-mail or call us. You can also fill the contact form on the left, we will get in touch with you.

+ 31 180-415711
info@elinex.com

Contact.

Sign up for the Elinex newsletter:

13 November 2018 - 10:10 - Wij zijn er klaar voor om de bezoekers van het @ITRoomInfra event te informeren over de noodzaak van onze producten… https://t.co/9TK9GBzKkt
2 November 2018 - 10:04 - Afgelopen woensdag stond voor Elinex in het teken van een feestelijke oplevering van de noodstroominstallatie bij… https://t.co/IDV3n4Jo5S
2 November 2018 - 09:01 - RT @KickStartEur: Huub van Raamsdonk, Managing Director @ElinexPS, shares his outlook into the near future: https://t.co/Ehfo6k12Uq. Chat w…
16 October 2018 - 08:47 - In de zomer van 2018 is Elinex partner geworden van @DutchDatacenter Huub van Raamsdonk, algemeen directeur Elinex:… https://t.co/TvTt1geKWu
8 October 2018 - 14:36 - Op 25 oktober vindt het IT Infrastructure Datacenters Congress plaats in Affligem, België. Elinex nodigt u van hart… https://t.co/ryETJGeDne
8 October 2018 - 08:54 - 'Machtige multinationals en besluiteloze politici zullen ons stroomtekort niet oplossen' https://t.co/3jsLkk1yHI vi… https://t.co/uoe8jwW2J6
5 October 2018 - 10:41 - Weer grote stroomstoring Schiphol: bagagebanden stil https://t.co/2wq80bpWQe via @telegraaf #watalsdestroomuitvalt
2 October 2018 - 11:04 - Sporten verhoogt de concentratie en productiviteit van medewerkers. De noodstroomspecialisten van Elinex vinden het… https://t.co/v3VheJoRdu
28 September 2018 - 12:02 - Thank you good old Eaton 9130 UPS! From this moment this model is End Of Life. Elinex happily sold more than 10.000… https://t.co/79VutaNa4H
26 September 2018 - 14:36 - Een dag op stap met service engineer Jeroen. Vandaag stond onderhoud van het UPS-systeem bij een instantie in Den H… https://t.co/c8OUZFEdyh
21 September 2018 - 13:42 - Het maintenance team van @Croonwolterdros was gisteren aanwezig voor de 2e UPS-training. In samenwerking met Huawei… https://t.co/zFk9fFmCAQ
21 September 2018 - 09:06 - Waarom is Nederland zo aantrekkelijk voor datacenters? | Blog | https://t.co/bW7L9yX6C2 https://t.co/qgNWPHDoJs
18 September 2018 - 11:30 - Stroomuitval in deel van Rotterdam West Robert Fruinstraat Rotterdam https://t.co/m8WmAkRKmd #watalsdestroomuitvalt
17 September 2018 - 16:31 - Vandaag viert Elinex een feestje! Onze enthousiaste en vrolijke collega Natascha is 12,5 jaar werkzaam bij Elinex.… https://t.co/vjsacJHw9c
11 September 2018 - 10:32 - ‘Succes moet je vieren!’ met dit motto heeft team Elinex haar succes en groei goed gevierd tijdens de jaarlijkse BB… https://t.co/R7VdK5hzCx
3 September 2018 - 14:46 - Elinex heeft ambitie en groeit hard. Vandaag starten 8 getalenteerde mensen die nodig zijn om die ambitie waar te m… https://t.co/4eO4NZuNVn
28 August 2018 - 08:51 - Grieks toeristeneiland zonder stroom - #ndnl #watalsdestroomuitvalt? https://t.co/XJWYwm3k5c
23 August 2018 - 13:43 - En dan denken wij aan Brabant, want daar brandt nog licht! #aggregaat #august #brabant #efteling #etz #guusmeeuwis… https://t.co/UUmIWMoiiD
14 August 2018 - 09:41 - Ons nieuwe teamlid Annelies liep een dagje mee met service engineer Eric. #watalsdestroomuitvalt? https://t.co/uHRIp0r8eq
10 August 2018 - 15:34 - “De vakkundigheid, rust en klantvriendelijkheid van alle medewerkers van Elinex vielen op. Dit is klantbeleving zoa… https://t.co/rjqtF8Mhes